Delfield N8600 Specifications Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
N8000 Series Drop-In Installation and Operation Manual
11
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
Installation
N8000, N8000N, N8000-R, N8100B, N8100NB, N8100-BR, N8200, N8200-ST, N8200G, N8100-FA & 8100-EF
These units are intended for indoor use only. A room
temperature of no more than 86°F (30°C) is recommended.
Be sure the location chosen has a counter strong enough to
support the total weight of the unit and contents. A fully loaded
model may weigh as much as 600 pounds! Reinforce the
counter as necessary to provide maximum loading.
Unit requires that the sides and bottom are not
any closer than 3” (7.6cm) to any combustible
material.
The counter cut-out sizes and power requirements are shown
on the specication pages. A gasket is installed in the ange
of each unit. The weight of the unit on the gasket forms a seal
preventing liquids from seeping into the cut-out opening.
Louvers
Self-contained refrigerated units (N8100, N8100NB, N8100-BR,
N8200, N8200-ST and N8200G Series) require airow to the
compressor. A 13” x 25” (33 cm x 63.5 cm) louver is provided
by Deleld and must be installed in the counter in front of the
condenser. The louver cutout dimension is 11” x 22” (27.9 cm
x 55.9 cm). The rear must have an opening to permit removal
of heated air. The opening must be at least 8” x 11”, a total of
88 square inches (20.3 cm x 27.9 cm, a total of 566 square
centimeters).
Plumbing
The units drain must have an outlet to an appropriate drainage
area or container. A drain trap must be installed. N8200 and
N8200-ST series have 1/2” drain and N8200G series have 3/4”
drain located on end/center. The 1” diameter drain on N8000,
N8000-R, N8100, N8100NB, N8100-BR, N8100-FA and 8100-
EF Series units is shipped loose and must be connected during
installation. N8157-FA, N8169-FA, and N8182-FA have two
drains.
Moisture collecting from improper drainage
can create a slippery surface on the oor
and a hazard to employees. It is the owner’s
responsibility to provide a container or outlet
for drainage.
Some N8000, N8000N, N8000-R, N8100B,
N8100NB and N8100-BR may have polyethylene
insulation in the drain hole. This can easily be
cut out without any contact or damage to the
units interior insulation or refrigeration lines.
Electrical connection
Refer to the amperage data on the specication pages, the
serial tag or your local code to be sure the unit is connected
to the proper power source. A protected circuit of the correct
voltage and amperage must be run for con nec tion of the line
cord.
Some units have an ON/OFF switch located behind the
louvered panel in the machine compartment. Simply turn the
switch to ON to begin operation.
Some units have an OFF position on the thermostat dial
which is located behind the louvered panel in the machine
compartment. Simply turn the dial to begin operation.
The unit must be disconnected from the
power source whenever performing service or
maintenance functions.
Never operate the unit without the louvered
panel in place!
DANGER
Installation N8600
These units are intended for indoor use only. A room temperature
of no more than 86°F (30°C) is recommended. Be sure the
location chosen has a counter strong enough to support the
total weight of the unit and contents. A fully loaded model
may weigh as much as 600 pounds! Reinforce the counter as
necessary to provide for maximum loading.
Unit requires that the sides and bottom are not
any closer than 3” (7.6cm) to any combustible
material.
The counter cut-out sizes and power requirements are shown
on the specication pages. A gasket is installed in the ange
of each unit. The weight of the unit on the gasket forms a seal
preventing liquids from seeping into the cut-out opening.
The cut-out dimensions for the control box on N8600 Series
units is 4.25” x 12.25” (10.8 cm x 31.1 cm).
Louvers
For proper refrigerated operation, N8600 Series units require
airow to the compressor. A 13” x 25” louver is (33.0 cm x 63.5
cm) is provided by Deleld and must be installed in the counter
in front of the condenser. The louver cutout dimension is 11”
x 22” (27.9 cm x 55.9 cm). The rear must have an opening to
permit removal of heated air. The opening must be at least 8” x
11”, a total of 88 square inches (20.3 cm x 27.9 cm, a total of 566
square centimeters).
Plumbing
The units 1” (2.54cm) drain must have an outlet to an appropriate
drainage area or container.
Moisture collecting from improper drainage
can create a slippery surface on the oor
and a hazard to employees. It is the owners
responsibility to provide a container or outlet
for drainage.
Electrical connection
Refer to the amperage data on the specication pages, the
serial tag or your local code to be sure the unit is connected to
the proper power source.
The unit must be disconnected from the
power source whenever performing service
or maintenance functions.
Never operate the unit without the louvered
panel in place!
CAUTION
DANGER
Page view 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 35 36

Comments to this Manuals

No comments