Delfield F17 Series Installation Manual Page 9

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 8
F2000/F17 Series Equipment Stand Service and Installation Manual
9
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
Temperature Control Settings, Self Contained Refrigerators And Freezers
A thermostat controls temperature in self contained refrigerators
and freezers. Thermostats are located in the machine
compartment inside a splash resistant enclosure. Slide the
enclosure cover back to access the thermostat. They are field
adjustable and do not require a service agent. The factory setting
for refrigerators is 2.5. The factory setting for freezers is 4.5.
Set toward 1 for higher temperatures and toward 7 for lower
temperatures.
Please make small incremental adjustments if a
temperature adjustment is necessary. Contact the
service department at Delfield +1 (989) 773-7981 or
your local service agent for additional assistance.
Delfield is not responsible for charges incurred
while adjusting the thermostat.
Temperature Control Settings, Remote Freezers
The temperature control is located in the machine compartment.
It is field adjustable and does not require a service agent. The
factory setting for a remote freezer is 0°F cut-in with a 5°F
differential.
Please make small incremental adjustments if a
temperature adjustment is necessary. Contact the
service department at Delfield +1 (989) 773-7981 or
your local service agent for additional assistance.
Delfield is not responsible for charges incurred while
adjusting the thermostat.
Freezer base equipment stands are designed and pre-set at the
factory to maintain a temperature of 0°F to -5°F (-18°C to -21°C)
interior cabinet temperature at 100°F (38°C) ambient room
temperature. Self-contained units have a digital thermometer
installed in the removable louver. The digital thermometer for
remote units is located in the removable access panel.
Freezer Evaporator Fan Operation
The evaporator fan(s) and condenser fan will cycle off and on with
the compressor to conserve energy. The temperature control will
cycle the compressor and condenser fan motor and evaporator
fan motor to maintain box temperature at the control setting.
Cooling Cycle Defrost Cycle
All Freezers
Self-Contained
Freezers
Remote Freezers
Compressor
On
Compressor
Off
Compressor
On
Compressor
Off
Evap Fan On Evap Fan Off Evap Fan Off Evap Fan Off
Freezer Defrost
Self-contained models use hot gas to defrost the evaporator coils.
Remote freezers use electric defrost.
Operation: Freezer Base Equipment Stands
Page view 8